Current Transformers

transfers accurately proportional levels of current to multiple circuits.


Showing results: 211 - 225 of 340 items found.

  • Burn Down Transformer

    ATG 2 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level

  • Burn Down Transformer

    ATG 6000 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

  • Surge Arrester Testing

    Weshine Electric Manufacturing Co., Ltd

    This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.

  • Instrument Transformers Tester

    TE30 - Calmet Smart Calibration Devices

    Electricity meters tester class 0.05 and 0.1. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.

  • Current Sensors

    Measurlogic

    Measurlogic offers an array of current sensors for every need, including split core, solid core and Rope current transformers (CTs); DC Shunts and Hall Effect Sensors. All of our electrical sensors are designed with an easy, un-intrusive installation in mind. With a low cost and high accuracy guarantee, we provide top of the line solutions for measurement and cost savings for residents and business owners alike.

  • - RS-232 to Current Loop Converter

    Model 65A - Telebyte, Inc.

    FEATURES: Active/Passive Loops; 20 or 60 mA. Operation; DC To 19.2 KBPS; Half/Full Duplex; Optically Isolated; DTE/DCE Selectable. The Model 65A is a small, versatile, RS-232 to Current Loop Converters for use with teletypes or computers providing local terminal input via a 20mA. (or 60 ma.) current loop. The Model 65 includes a wall mounted transformer and internal power supply circuitry.

  • Low-Voltage Arrester Analyzer

    Weshine Electric Manufacturing Co., Ltd

    1. This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.

  • 10 A portable digital micro-ohmmeter

    MPK-253 - MEGABRAS srl

    The MPK-253 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10 A.

  • AC / DC Combined High Voltage Test Set

    Cambridge Instruments & Engineering Co.

    suitable to perform AC High Voltage Power Frequency test on transformers, motors, cables etc. Leakage current can be measured at desired pressure and this set can be used as a source for cable fault burning.

  • Megohm Meter

    Fieldpiece Instruments, Inc

    Digital Megohm Meter, model SMG5, is a compact standalone meter designed for checking HVAC compressor insulation. The SMG5 provides a 1000V voltage source, monitors current, and displays the resistance between the test points. Maximum current output is <1mA. It can be used to determine the condition of insulation from winding to ground in a motor, compressor, or transformer. Includes a case, alligator clip lead tip and leads with removable tips.

  • 5 A portable digital micro-ohmmeter

    MPK-254 - MEGABRAS srl

    The MPK-254 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1 mA up to 5 A.

  • Dekatran Decade Ratio Transformer

    DT1145 - TEGAM Inc.

    The DT1145 is TEGAM''s only bench or panel mountable, decade transformer solution. It features three decades plus an interpolating potentiometer for fine tune adjustment of ratio signals to 1.11100. The unit has an exceptionally low output impedance for high current applications of up to 1 Ampere.

  • Transformer and Reactor Loss Measurement System

    Measurements International Ltd.

    The measurement of electric power and energy at high voltages and currents at low power factors is becoming increasingly important economically as a way to reduce costs in an ever-growing industrial economy. Today the transformer purchaser subjects the transformer manufacturer to an economic penalty for losses that occur in load and no-load conditions. To keep these penalties as low as possible, it is important that the manufacturer accurately measure these losses. Failure to do so can result in the manufacturer losing important contract awards to their competitors who may be utilizing a more accurate system. Using “State of the Art” proven two-stage-currentcomparator technology, the AccuLoss™ Series of transformer loss measurement systems is designed to meet the needs of today’s transformer manufacturer by providing the most accurate power loss measurement system in the world. Designed for power frequency testing and calibration, the AccuLoss™ system can be used for testing small, medium and large power transformers as well as motors and turbines up to 400 Hz. The system is also ideal for R&D facilities. The AccuLoss™ system can also be used to measure losses in single and three phase reactors.

  • Toroid Core Coil Turns Testers

    SS107A - Sanshine Electronis Co., Ltd.

    The magnetic torrid ring core winding coil turns tester (SS107A) adopts the high speed center microprocessing unit circuits and precise measurement A/D circuits. This coil turns tester is used to count the coil turns of various torrid core winding coils. Like as: torrid core inductors, torrid core transformers, torrid core sensors, wate meter sensors, torrid current transformers, torrid core choke coils, etc. The tone tester is named magnetic ring core coil turn tester also.